Interpretive search of optimal isocratic and gradient separations in micellar liquid chromatography in extended
J A Navarro-Huerta1, A G Vargas-García1, J R Torres-Lapasió1
1Department of Analytical Chemistry, Faculty of Chemistry, Universitat de València, c/ Dr. Moliner 50, 46100 Burjassot, Spain.
Abstract:
Micellar liquid chromatography (MLC) is a reversed-phase mode with mobile phases containing an organic solvent and a micellised surfactant. Most procedures developed in MLC are implemented in the isocratic mode, since the general elution problem in chromatography is less troublesome. However, gradient elution may be still useful in MLC to analyse mixtures of compounds within a wide range of polarities, in shorter times. MLC using gradients is attractive to determine by direct injection moderate to low polar compounds in physiological samples. In these analyses, the use of initial micellar conditions (isocratic or gradient) with a fixed amount of surfactant above the critical micellar concentration, keeping the organic solvent content low, will provide better protection of the column against the precipitation of the proteins in the physiological fluid. Once the proteins are swept away, the elution strength can be increased using a positive gradient of organic solvent to reduce the analysis time. This may give rise to the transition from the micellar to the submicellar mode, since micelles are destroyed at sufficiently high concentration of organic solvent. In this work, several retention models covering extended solvent domains in MLC are developed and tested, and applied to investigate the performance in isocratic, linear and multi-linear gradient separations. The study was applied to the screening of β-adrenoceptor antagonists in urine samples, using mobile phases prepared with sodium dodecyl sulphate and 1-propanol. Predicted chromatograms were highly accurate in all situations, although suffered of baseline problems and minor shifts for peaks eluting close to a steep gradient segment. Two columns (C18 and C8) were investigated, with the C8 column being preferable owing to the smaller amount of adsorbed surfactant.
More Related Videos
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
10:32On-chip Isotachophoresis for Separation of Ions and Purification of Nucleic Acids
Published on: March 2, 2012
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: