Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Single-Particle Tracking and Trajectory Analysis of Fluorescent Nanodiamonds in Cell-Free Environment and Live Cells.

Small (Weinheim an der Bergstrasse, Germany)·2022
Same author

Deterministic Lateral Displacement: Challenges and Perspectives.

ACS nano·2020
Same author

Lab-on-a-Chip Technologies for the Single Cell Level: Separation, Analysis, and Diagnostics.

Micromachines·2020
Same author

The Fate of Lipid-Coated and Uncoated Fluorescent Nanodiamonds during Cell Division in Yeast.

Nanomaterials (Basel, Switzerland)·2020
Same author

Matrix-masking to balance nonuniform illumination in microscopy.

Optics express·2018
Same author

Microfluidic Devices for Drug Assays.

High-throughput·2018

Related Experiment Video

Updated: Jan 1, 2026

Procedure for the Development of Multi-depth Circular Cross-sectional Endothelialized Microchannels-on-a-chip
10:55

Procedure for the Development of Multi-depth Circular Cross-sectional Endothelialized Microchannels-on-a-chip

Published on: October 21, 2013

14.3K

Presegmentation Procedure Generates Smooth-Sided Microfluidic Devices: Unlocking Multiangle Imaging for Everyone?

Axel Hochstetter1,2

  • 1Division of Infection Medicine, Department of Clinical Sciences, Lund University, Lund 221 84, Sweden.

ACS Omega
|December 24, 2019
PubMed
Summary
This summary is machine-generated.

We developed a simple method for creating transparent polymer microfluidic devices with smooth sides. This technique enables rapid multiangle imaging, overcoming limitations of conventional polymer fabrication methods.

More Related Videos

Microstructured Devices for Optimized Microinjection and Imaging of Zebrafish Larvae
07:40

Microstructured Devices for Optimized Microinjection and Imaging of Zebrafish Larvae

Published on: December 8, 2017

10.2K
Multi-step Variable Height Photolithography for Valved Multilayer Microfluidic Devices
10:18

Multi-step Variable Height Photolithography for Valved Multilayer Microfluidic Devices

Published on: January 27, 2017

14.9K

Related Experiment Videos

Last Updated: Jan 1, 2026

Procedure for the Development of Multi-depth Circular Cross-sectional Endothelialized Microchannels-on-a-chip
10:55

Procedure for the Development of Multi-depth Circular Cross-sectional Endothelialized Microchannels-on-a-chip

Published on: October 21, 2013

14.3K
Microstructured Devices for Optimized Microinjection and Imaging of Zebrafish Larvae
07:40

Microstructured Devices for Optimized Microinjection and Imaging of Zebrafish Larvae

Published on: December 8, 2017

10.2K
Multi-step Variable Height Photolithography for Valved Multilayer Microfluidic Devices
10:18

Multi-step Variable Height Photolithography for Valved Multilayer Microfluidic Devices

Published on: January 27, 2017

14.9K

Area of Science:

  • Materials Science
  • Biotechnology
  • Optical Engineering

Background:

  • Microfluidic devices are crucial for various scientific applications.
  • Conventional fabrication methods often result in turbid side planes, hindering optical analysis.
  • Smooth surfaces are desirable for advanced imaging techniques.

Purpose of the Study:

  • To present a simple procedure for fabricating smooth-sided, transparent polymer microfluidic devices.
  • To investigate the impact of smooth side planes on multiangle imaging capabilities.
  • To compare the developed method with existing techniques and microscopy modalities.

Main Methods:

  • Presegmentation of polymer substrates using hydrophobized glass slides.
  • Fabrication of transparent polymer-based microfluidic devices.
  • Multiangle imaging and comparison with conventional microscopy (widefield, confocal, 2-photon).
  • Three-dimensional (3D) rendering analysis.

Main Results:

  • The developed procedure successfully created smooth-sided, transparent microfluidic devices.
  • Smooth side planes significantly improved the quality and speed of multiangle imaging compared to turbid surfaces.
  • The approach demonstrated compatibility with various advanced microscopy techniques.

Conclusions:

  • Presegmentation with hydrophobized glass slides is an effective method for fabricating high-quality microfluidic devices.
  • The resulting smooth surfaces enhance optical imaging capabilities, enabling advanced 3D analysis.
  • This technique offers a promising alternative for microfluidic device fabrication with broad applications in research and diagnostics.