Related Experiment Video
Updated: Jan 1, 2026

Author Spotlight: An Economic and Efficient Method for Quantitative Evaluation of Bone Microarchitecture in a Murine Osteoporosis Model
Published on: September 8, 2023
Visualization of woven bone structure through analysis of biopsy specimens using synchrotron radiation and
1Department of Periodontology, School of Dentistry, Kyungpook National University, Daegu 41940, Republic of Korea.
Abstract:
This study explores the application of synchrotron radiation and conventional microcomputed tomography (SR-µCT and C-µCT, respectively) in evaluating bone-biopsy specimens. Bone-biopsy specimens were obtained using a trephine bur during bone-graft removal for implant placement six months after performing a maxillary sinus bone-graft procedure. Image data of specimens were obtained using SR-µCT and C-µCT. SR-µCT was performed using the 6C biomedical imaging beamline at the Pohang Accelerator Laboratory with a monochromatic X-ray beam of 23 keV, and C-µCT was performed using a table-top CT scanner (Skyscan 1272). Reconstruction images obtained using the two methods were qualitatively compared with 2D images evaluated under 3D visualization. The SR-µCT images, especially of the new-bone-graft-woven-bone formation, were less noisy and sharper than the C-µCT images. To evaluate the new-bone-graft-woven-bone formation, only the SR-µCT images showed areas of new bone (NB) formation with bone substitute (BS; Bio-Oss) and woven bone (WB) contact, and correctly visualized true 3D structures of bone formation. Hence, µCT techniques are non-destructive and can provide detailed images of bone biopsy. In particular, SR-µCT can be used to obtain improved image quality with contrast of NB, BS and WB, demonstrating a level of detail comparable with bone formation. SR-µCT could be an unbiased 3D alternative for imaging WB formation and for high-throughput analysis.
More Related Videos
07:10A Sectioning, Coring, and Image Processing Guide for High-Throughput Cortical Bone Sample Procurement and Analysis for Synchrotron Micro-CT
Published on: June 12, 2020
08:51Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography
Published on: May 27, 2008
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Bone Structure
Gross Anatomy of Bone
The diaphysis is the tubular shaft that runs between the proximal and distal ends of the bone. The walls of the diaphysis are composed of dense and hard compact bone made of numerous osteons — the functional unit of the compact bone. The hollow region in the diaphysis is called the medullary cavity, which harbors the bone marrow. In infants and children, this marrow cavity is filled with red marrow, whereas in...