Related Experiment Video
Updated: Aug 3, 2026

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Microdosimetry near the trajectory of high-energy heavy ions
N F Metting1, H H Rossi, L A Braby
1Pacific Northwest Laboratory, Richland, Washington 99532.
Abstract:
Single-event energy distributions were measured in a 1.3-micron-diameter site as a function of radial distance from the trajectory of high-energy iron ions having an energy of about 600 MeV/amu. It was found that beyond distances of a few micrometers the average lineal energy of the (mostly single) secondary electrons (delta rays) is of the order of 3 keV/micron. This is similar to the value found in a medium irradiated by 170-keV photons. The frequency-mean specific energy for delta rays occurring at large distances from the path of the primary ion exceeds the calculated (radial) absorbed dose by two orders of magnitude.