Shi-Feng Xiang1, Xue-Qiang Zhang2, Su-Jun Yang1
1Handan Central Hospital, 15 Southern Zhonghua Street, Handan City, Hebei Province, 056001, China.
Abstract:
Currently, little is known regarding the value of quantitative parameters derived from the intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) with integrated slice-specific shimming (iShim) sequence in detecting old myocardial infarction and myocardial fibrosis. This study was to investigate the value of IVIM-MRI with iShim sequence in diagnosing old myocardial infarction and fibrosis. Thirty-five patients with both old myocardial infarction and myocardial fibrosis and 12 healthy volunteers were prospectively enrolled to undergo cardiac diffusion-weighted imaging (DWI) using seven b-values (0, 20, 60, 80, 120, 200 and 600 s/mm2). The iShim sequence was used for IVIM data acquisition, and the diffusion parameters, D, D* and f values for IVIM, and conventional apparent diffusion coefficient (ADC) were evaluated on the anterior, posterior and lateral walls of the ventricular septum using the short axis of the heart. Significant differences were found in the D, D* and f values between healthy subjects and patients with old myocardial infarction and myocardial fibrosis (P = 0.000), with the median value of the D and f significantly smaller in the myocardial infarction and fibrosis than in the normal control but the median value of D* significantly greater in the myocardial infarction and fibrosis than in the normal control. In the receiver operating curve analysis, the areas under the curve were 0.939, 0.988 and 0.959 for the D, D* and f values, respectively. The sensitivities and specificities were 84.6% and 94.4% for D, 88.9% and 84.6% for D* and 100% and 93.1% for the f values, respectively. In conclusion, the IVIM-derived parameters (D, D* and f) obtained using the iShim DWI technique showed high capacity in diagnosing old myocardial infarction and myocardial fibrosis by providing diffusion and perfusion information, which may have great importance in future clinical practice.
Insights
Intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) with integrated slice-specific shimming (iShim) effectively diagnoses old myocardial infarction and fibrosis. IVIM parameters (D, D*, and f) show high accuracy, offering valuable clinical insights for heart conditions.
Area of Science:
- Cardiovascular Imaging
- Radiology
- Biomedical Engineering
Background:
- Detecting old myocardial infarction and fibrosis using quantitative MRI parameters remains challenging.
- Intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) offers potential for tissue characterization.
- The utility of IVIM with integrated slice-specific shimming (iShim) for these conditions is not well-established.
Purpose of the Study:
- To evaluate the diagnostic value of IVIM-MRI with iShim sequence for old myocardial infarction and fibrosis.
- To assess quantitative IVIM parameters (D, D*, f) and apparent diffusion coefficient (ADC) in affected myocardial tissue.
Main Methods:
- Prospective enrollment of 35 patients with old myocardial infarction/fibrosis and 12 healthy volunteers.
- Cardiac diffusion-weighted imaging (DWI) using seven b-values (0-600 s/mm²) with iShim sequence.
- Analysis of IVIM parameters (D, D*, f) and ADC in ventricular septum walls.
Main Results:
- Significant differences in D, D*, and f values between healthy subjects and patients (P < 0.001).
- Median D and f were lower, while median D* was higher in patients compared to controls.
- Receiver operating curve analysis showed high areas under the curve (0.939-0.988) for D, D*, and f, with excellent sensitivity and specificity.
Conclusions:
- IVIM-derived parameters (D, D*, f) using the iShim DWI technique demonstrate high diagnostic capacity for old myocardial infarction and fibrosis.
- These parameters provide crucial diffusion and perfusion information, indicating significant potential for clinical application.
- This advanced MRI technique may enhance the diagnosis and management of myocardial scarring.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...