Cost-Effective Detection of Perfluoroalkyl Carboxylic Acids with Gas Chromatography: Optimization of Derivatization
Zhen Li1,2, Hongwei Sun1,3
1Key Laboratory of Pesticide & Chemical Biology of Ministry of Education, Institute of Environmental & Applied Chemistry, College of Chemistry, Central China Normal University, Wuhan 430079, China.
Abstract:
The reliable quantification of perfluoroalkyl carboxylic acids (PFCAs) in environmental samples like surface water by using gas chromatography (GC) remains challenging because the polar PFCAs call for derivatization before injection and problems involving the integration of sample pretreatment and derivatization procedures. Here we proposed a cost-effective method for the GC based determination of C4-C12 PFCAs in surface water samples by integrating solid phase extraction and PFCAs anilide derivatization. First, we assessed the performance of different PFCAs derivatization methods, namely esterification and amidation. Esterification was unable to derivatize C4-C6 PFCAs. On the contrary, amidation procedures by using 2,4-difluoroaniline (DFA) and N,N'-dicyclohexylcarbodiimide (DCC) could successfully transform all the PFCA analogs to produce anilide derivatives, which could be easily detected by GC. Then the reaction conditions in the amidation approach were further optimized by using orthogonal design experiments. After optimizing the instrumental parameters of GC, the limits of detection (LOD) of this derivatization method were determined to be 1.14-6.32 μg L-1. Finally, in order to establish an intact method for the quantification of PFCAs in surface water samples, solid phase extraction (SPE) was used for extraction and cleanup, which was further integrated with the subsequent amidation process. The SPE-amidation-GC method was validated for application, with good accuracy and precision reflected by the PFCAs recoveries and derivatization of triplicates. The method reported here could provide a promising and cost-effective alternative for the simultaneous determination of C4-C12 PFCAs in environmental water samples.
More Related Videos
11:06GC-based Detection of Aldononitrile Acetate Derivatized Glucosamine and Muramic Acid for Microbial Residue Determination in Soil
Published on: May 19, 2012
11:08The Use of Gas Chromatography to Analyze Compositional Changes of Fatty Acids in Rat Liver Tissue during Pregnancy
Published on: March 13, 2014
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Performance Liquid Chromatography: Types of Detectors