Published on: February 7, 2014
Validity of single-point assessments for determining leg pulse wave velocity in sitting and supine positions
Simon Fryer1, Keeron Stone1, Gabriel Zieff2
1School of Sport and Exercise, University of Gloucestershire, Gloucester, UK.
Abstract:
There has been a great deal of interest into the effects of prolonged sitting on lower limb vascular function. However, most studies use flow-mediated dilation which is technically challenging. A simpler technique is pulse wave velocity (PWV) which can be estimated at any single arterial site of interest using a number of different calculations (Bramwell-hill [PWVBH ], β-stiffness index [PWVβ ] and blood flow [PWVBF ]). Findings from this technique would be better inferred if they compare to a standard criterion 2-point PWV assessment. The current study used ultrasound to determine which estimation of single-point PWV is most valid. The criterion was traditional ECG-gated 2-point (superficial femoral [SF]-posterior tibialis [PT]) PWV. Single-point estimates were calculated at the SF and PT arteries in both supine and seated positions. Single-point PWV was considered valid if the aSEE was <1.0 m·s. Findings show that for both postural positions, the absolute standard error of estimates (aSEE) criterion of <1.0 m·s was not achieved in either the PT or SF arteries using any of the single-point PWV calculations. However, single-point calculations consistently demonstrated the lowest error at the SF artery using PWVβ in both supine (SF aSEE = 1.7 vs. PT 2.7 m·s) and seated (SF aSEE = 1.5 vs. PT 3.0 m·s) positions. All single-point ΔPWV (supine - seated) calculations were higher in sitting, with PWVβ having the closest agreement (ΔSF aSEE 1.7 m·s) to the 2-point criterion. Single-point PWV calculations do not directly reflect regional 2-point PWV. However, they are sensitive to change when moving from supine to seated positions.
Related Concept Videos
Pulse Assessment Sites
Assessing Blood pressure in the Leg
Preparation:
Special considerations while measuring pulse
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...