Oesophageal Cancer: Conformal Radiotherapy vs. Hybrid-VMAT Technique With Two Different Treatment Planning Systems
Related Experiment Video
Updated: Jan 1, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Masayoshi Miyazaki1,2, Shingo Ohira2,3, Yoshihiro Ueda2,3
1Department of Radiology, Hyogo College of Medicine, Hyogo, Japan masayoshi.miyazaki@gmail.com.
Background/Aim:
Traditionally, the radiotherapy of oesophageal cancer has been conformal radiotherapy (CRT). We sought to compare dosimetric parameters of conformal radiotherapy (CRT) with those of two treatment planning systems for hybrid-volumetric modulated arc therapy (h-VMAT) for the treatment of oesophageal cancer.
Patients And Methods:
In 11 patients, we compared: i) planning target volume coverage, ii) dose to organs at risk, and iii) the dose rate (DR) of the three techniques. We evaluated two treatment planning systems: i) Eclipse and ii) RayStation.
Results:
The Conformity Index of the CRT plan was significantly higher for the h-VMAT plans, compared to all other parameters. Normal lung tissue volumes receiving >5, 13, or 20 Gy were lower with the RayStation plan compared to Eclipse. The volume of cardiac tissue receiving >40 Gy was highest with the CRT plan. The minimum DR in VMAT was lowest for the RayStation plan (49.5 MU/min).
Conclusion:
The h-VMAT plan using RayStation is the appropriate choice for reducing lung dose.