On second-order calibration based on multivariate curve resolution in the presence of highly overlapped profiles
Mirta R Alcaraz1, María J Culzoni2, Gabriela A Ibañez3
1Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional Del Litoral, Ciudad Universitaria, 3000, Santa Fe, Argentina; Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2290, 1425, Buenos Aires, Argentina; Departamento de Química Inorgánica, Analítica y Química Física, INQUIMAE, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Intendente Güiraldes 2160, Ciudad Universitaria, Pabellón 2, 1428, Buenos Aires, Argentina.
Abstract:
Multivariate curve resolution has been applied to both simulated and experimental data sets where high or even complete overlapping occurs between component profiles in one data mode. It is shown that rotational ambiguity exists in the bilinear decomposition of the augmented data matrices built with second-order data for pure analyte standards and test samples containing uncalibrated interferents. However, even in the presence of rotational ambiguity, initialization based on the so-called purest variables in one of the data modes may allow one to develop analytical protocols with reasonable statistical indicators for the prediction of the analyte of interest. In one of the explored experimental systems, the analyte ciprofloxacin was determined in the presence of the interferent salicylate, measuring time decay-luminescence matrix data. The average prediction error was 0.02 mg L-1 in the test set, corresponding to a relative error of ca. 8%. In the second system, capillary electrophoresis with UV detection was employed to determine ciprofloxacin in aqueous samples in the presence of other fluoroquinolones, achieving analyte recoveries in the range 101-113%. Although further theoretical work may still be needed, the present analysis of the feasible component profiles after bilinear decomposition provides some clues to interpret the phenomenon.
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Profile Leveling and Cross Sections
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Curve Equations