Related Experiment Video
Updated: Jan 1, 2026

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
CT in planning transcatheter aortic valve implantation procedures and risk assessment
A Yucel-Finn1, E Nicol2, J A Leipsic3
1Royal Papworth Hospital, Cambridge, UK.
Abstract:
For surgical aortic valve replacement, the Society of Thoracic Surgeons score (STSS) is the reference standard for the prediction of operative risk. In transcatheter aortic valve implantation (TAVI) though, where the procedure itself is minimally invasive, the traditional risk assessment is supplemented by CTA. Through a consistent approach to the acquisition of high-quality images and the standardised reporting of annular measurements and adverse root and vascular features, patients at risk of complications can be identified. In turn, this may allow for a personalised procedural approach and treatment strategies devised to potentially reduce or mitigate this risk. This article provides a systematic and standardised approach to pre-procedural work-up with computed tomography angiography (CTA) and explores the current state of evidence and future areas of development in this rapidly developing field.
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Cardiac Catheterization III: Left Heart Catheterization
Aneurysm IV: Nursing Management