Related Experiment Video
Updated: Jan 1, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
OPTIMIZATION OF RADIATION DOSE IN CT IMAGING: ESTABLISHING THE INSTITUTIONAL DIAGNOSTIC REFERENCE LEVELS AND PATIENT
Mohd Amir Syahmi Mat Razali1, Muhamad Zabidi Ahmad1, Ibrahim Lutfi Shuaib1
1Oncological and Radiological Sciences Cluster, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Sains@Bertam, 13200 Kepala Batas, Penang, Malaysia.
Abstract:
The aim of this study was to propose local diagnostic reference levels (LDRLs) for the most common computed tomography (CT) examinations (including contrast and non-contrast scan phase) performed at Advanced Medical and Dental Institute (AMDI), Universiti Sains Malaysia (USM), Malaysia. A retrospective CT dose survey of 1488 subjects from January 2015 until December 2018 was performed at AMDI USM, Malaysia. The proposed DRLs were established at 50th and 75th percentile of dose distribution for all dose metrics (CT dose index [CTDI]; CTDIvol, CTDIw and dose-length product). The proposed LDRLs were compared with national DRLs and other established DRLs. The 10 most common CT examinations at AMDI were thorax-abdomen-pelvis (TAP) CT (46%), followed by pelvis CT (17%), abdomen-pelvis CT (10%), brain/head CT (9%) and other CT protocols. The local DRLs were established using the third quartile values of dose distribution and were categorized based on CT region protocols. Most of the proposed DRLs were exceeded the national DRLs (63%) and other international DRLs (67%). From the dose auditing, almost half of the recent dose data (for year 2018) exceeded the proposed local DRLs and the unusual dose were observed in TAP, brain/head and pelvis CT examinations. The unusual higher dose could be due to higher mAs settings, higher number of scan phase for contrast study and higher pitch factor. The local DRLs should be established for dose optimization and reduction of the occurrence of excessive radiation exposure to the patients. The establishment of the Ads and LDRLs should also consider all the factors that affect the variation in DRLs such as CT technology, scanning protocols and population characteristics. The local dose distribution should always be revised for improvement of the current local practice.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging
Imaging Studies III: Computed Tomography

