Related Experiment Video
Updated: Jul 27, 2026

4D Imaging of Protein Aggregation in Live Cells
Published on: April 5, 2013
A multi-channel in situ light scattering instrument utilized for monitoring protein aggregation and liquid dense
Sven Falke1,2, Hévila Brognaro1,3, Arayik Martirosyan1
1University Hamburg, Institute of Biochemistry and Molecular Biology, Laboratory for Structural Biology of Infection and Inflammation, c/o DESY, Build. 22a, Notkestr. 85, 22607, Hamburg, Germany.
Abstract:
Liquid-liquid phase separation (LLPS) phenomena have been observed in vitro as well as in vivo and came in focus of interdisciplinary research activities particularly aiming at understanding the physico-chemical pathways of LLPS and its functionality in recent years. Dynamic light scattering (DLS) has been proven to be a most efficient method to analyze macromolecular clustering in solutions and suspensions with diverse applications in life sciences, material science and biotechnology. For spatially and time-resolved investigations of LLPS, i.e. formation of liquid dense protein clusters (LDCs) and aggregation, a novel eight-channel in situ DLS instrument was designed, constructed and applied. The real time formation of LDCs of glucose isomerase (GI) and bovine pancreatic trypsin inhibitor (BPTI) under different physico-chemical conditions was investigated in situ. Complex shifts in the particle size distributions indicated growth of LDCs up to the μm size regime. Additionally, near-UV circular dichroism spectroscopy was performed to monitor the folding state of the proteins in the process of LDC formation.
More Related Videos
09:15Growing Protein Crystals with Distinct Dimensions Using Automated Crystallization Coupled with In Situ Dynamic Light Scattering
Published on: August 14, 2018
06:49Monitoring Protein Aggregation Kinetics In Vivo using Automated Inclusion Counting in Caenorhabditis elegans
Published on: December 17, 2021
Related Concept Videos
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.