Glucose Variability Assessed with Continuous Glucose Monitoring: Reliability, Reference Values, and Correlations with
Yuri D Foreman1,2, Martijn C G J Brouwers2,3, Carla J H van der Kallen1,2
1Department of Internal Medicine, Maastricht University Medical Center+, Maastricht, the Netherlands.
Abstract:
Glucose variability (GV) measured by continuous glucose monitoring (CGM) has become an accepted marker of glycemic control. Nevertheless, several methodological aspects of GV assessment require further study. We, therefore, investigated the minimum number of days needed to reliably measure GV, assessed GV reference values, and studied the correlation of GV with established glycemic indices (i.e., HbA1c, seven-point oral glucose tolerance test [OGTT]-derived indices). We used cross-sectional data from The Maastricht Study, an observational population-based cohort enriched with type 2 diabetes. Participants with more than 48 h of CGM (iPro2; Medtronic) were included for analysis (n = 851; age: 60 ± 9years; 49% women; 23% type 2 diabetes). We used mean sensor glucose (MSG), standard deviation (SD), and coefficient of variation (CV) as CGM-derived indices (the latter two for GV quantification). We calculated reliability using the Spearman-Brown prophecy formula, established reference values by calculating 2.5th-97.5th percentiles, and studied correlations using Spearman's rho. Sufficient reliability (R > 0.80) was achieved with two (MSG and SD), or three monitoring days (CV). The reference ranges, assessed in individuals with normal glucose metabolism (n = 470), were 90.5-120.6 mg/dL (MSG), 7.9-24.8 mg/dL (SD), and 7.74%-22.45% (CV). For MSG, the strongest correlation was found with fasting plasma glucose (rho = 0.65 [0.61; 0.69]); for SD, with the 1-h OGTT value (rho = 0.61 [0.56; 0.65]); and for CV, with both the incremental glucose peak (IGP) during the OGTT (rho = 0.50 [0.45; 0.55]) and the 1-h OGTT value (rho = 0.50 [0.45; 0.55]). The reliability findings and reference values are relevant for studies that aim to investigate CGM-measured GV. One-hour OGTT and IGP values can be used as GV indices when CGM is unavailable.
More Related Videos
Related Concept Videos
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion
Insulin and C-peptide are...
Glucose Absorption Into the Small Intestine