Related Experiment Video
Updated: Dec 31, 2025

Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
Online Concentration of Bacteria from Tens of Microliter Sample Volumes in Roughened Fused Silica Capillary with
Marie Horká1, Jiří Šalplachta1, Pavel Karásek1
1Institute of Analytical Chemistry of the CAS, Veveří 97, 602 00 Brno, Czech Republic.
Abstract:
This study presents a timely, reliable, and sensitive method for identification of pathogenic bacteria in clinical samples based on a combination of capillary electrophoresis with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. In this respect, a part of a single-piece fused silica capillary was etched with supercritical water with the aim of using it for static or dynamic cell-surface adhesion from tens of microliter sample volumes. The conditions for this procedure were optimized. Adhered cells of Staphylococcus aureus (methicillin-susceptible or methicillin-resistant) and of Pseudomonas aeruginosa were desorbed and preconcentrated from the rough part of the capillary surface using transient isotachophoretic stacking from a high conductivity model matrix. The charged cells were swep and separated again in micellar electrokinetic chromatography using a nonionogenic surfactant. Static adhesion of the cells onto the roughened part of the capillary is certainly volumetric limited. Dynamic adhesion allows the concentration of bacteria from 100 μL volumes of physiological saline solution, bovine serum, or human blood with the limits of detection at 1.8 × 102, 1.7 × 103, and 1.0 × 103 cells mL-1, respectively. The limits of detection were the same for all three examined bacterial strains. The recovery of the method was about 83% and it was independent of the sample matrix. A combination of capillary electrophoresis with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry required at least 4 × 103 cells mL-1 to obtain reliable results. The calibration plots were linear (R2 = 0.99) and the relative standard deviations of the peak area were at most 2.2%. The adhered bacteria, either individual or in a mixture, were online analyzed by micellar electrokinetic chromatography and then collected from the capillary and off-line analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry without interfering matrix components.
More Related Videos
14:12Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
10:05Large-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry
Published on: October 24, 2018
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...