Related Experiment Video
Updated: Dec 31, 2025

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Analysis of e-liquids for electronic cigarettes using GC-IMS/MS with headspace sampling
Edyta Budzyńska1, Stefanie Sielemann2, Jarosław Puton1
1Military University of Technology, Warsaw, Poland.
Abstract:
Electronic cigarettes (e-cigarettes) are continuously increasing in popularity due to being considered healthier compared with traditional cigarettes. Based on the European directive 2014/40/EU [1] the German legislation restricts the usage of potential harmful substances in these tobacco related products [2,3]. The aim of this work was to establish a method for the detection and quantification of selected substances covered by the above regulation. For this purpose, one-of-a-kind gas chromatograph with ion mobility spectrometer (GC-IMS) was used. Instrument was parallelly coupled with conventional chromatograph equipped with quadrupole mass spectrometer (GC-MS). Headspace (HS) was used as a sample preparation technique. During initial tests both systems were correlated by using a mixture of simple carbonyl compounds. The identification of the selected analytes was performed by mass spectrometry and calibration curves for the quantification were recorded. For all tested substances the limit of detection (LOD) and limit of quantification (LOQ) were determined. The LOD ranges are from 8 to 70 μg/L, the LOQ are from 25 to 200 μg/L. For testing the usability of the developed method 20 samples of commercially available refills for e-cigarettes (e-liquids), produced in Germany and Poland, were analyzed. Substances listed in the directive were found in all samples. In two of them an according to the regulations forbidden substance (estragole) was detected.
More Related Videos
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
08:39Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies
Published on: August 25, 2018
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...