Correction of the VIR-visible data set from the Dawn mission

B Rousseau1, A Raponi1, M Ciarniello1

  • 1IAPS-INAF, Via Fosso del Cavaliere 100, 00133 Rome, Italy.

Related Concept Videos

Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
236
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
772
Magnetic Declination01:19

Magnetic Declination

Magnetic declination is the angle between true north, which aligns with the Earth's rotational axis, and magnetic north, which follows the direction of the Earth's magnetic field. This discrepancy exists because the magnetic poles do not coincide with the geographic poles. The value of magnetic declination depends on the observer's location on Earth and is subject to changes over time due to the dynamic nature of the Earth's magnetic field.The declination is called eastern when magnetic north...
322
Errors in Global Positioning System01:26

Errors in Global Positioning System

Global Positioning System (GPS) technology has revolutionized navigation and positioning, but its accuracy is often compromised by various errors. These errors, stemming from environmental, satellite, and receiver-related factors, require careful mitigation to ensure reliable performance across applications.Atmospheric ErrorsGPS signals travel through the Earth’s ionosphere and troposphere, introducing delays which affect accuracy. The ionosphere is strongly influenced by charged particles,...
269
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
997
Flame Photometry: Overview01:02

Flame Photometry: Overview

Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
1.3K