A Simple Dewar/Cryostat for Thermally Equilibrating Samples at Known Temperatures for Accurate Cryogenic Luminescence Measurements
Published on: July 19, 2016
A uniform flow-cavity ring-down spectrometer (UF-CRDS): A new setup for spectroscopy and kinetics at low temperature
N Suas-David1, S Thawoos1, A G Suits1
1Department of Chemistry, University of Missouri, Columbia, Missouri 65211, USA.
Abstract:
The UF-CRDS (Uniform Flow-Cavity Ring Down Spectrometer) is a new setup coupling for the first time a pulsed uniform (Laval) flow with a continuous wave CRDS in the near infrared for spectroscopy and kinetics at low temperature. This high resolution and sensitive absorption spectrometer opens a new window into the phenomena occurring within UFs. The approach extends the detection range to new electronic and rovibrational transitions within Laval flows and offers the possibility to probe numerous species which have not been investigated yet. This new tool has been designed to probe radicals and reaction intermediates but also to follow the chemistry of hydrocarbon chains and PAHs which play a crucial role in the evolution of astrophysical environments. For kinetics measurements, the UF-CRDS combines the CRESU technique (French acronym meaning reaction kinetics in uniform supersonic flows) with the SKaR (Simultaneous Kinetics and Ring-Down) approach where, as indicated by its name, the entire reaction is monitored during each intensity decay within the high finesse cavity. The setup and the approach are demonstrated with the study of the reaction between CN (v = 1) and propene at low temperature. The recorded data are finally consistent with a previous study of the same reaction for CN (v = 0) relying on the CRESU technique with laser induced fluorescence detection.
Related Concept Videos
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...