Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood
Published on: April 16, 2016
Ultrasensitive self-enhanced electrochemiluminescence sensor based on novel PAN@Ru@PEI@Nafion nanofiber mat
Libo Li1, Limin Zhou, Xiaohong Liu
1Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Equipment Engineering, Institute of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China. youty@ujs.edu.cn.
Abstract:
In the present work, a novel self-enhanced electrochemiluminescence (ECL) composite was for the first time prepared by simply electrospinning a mixture of polyacrylonitrile (PAN), Ru(bpy)32+, poly(ethylenimine) (PEI) and Nafion, and defined as PAN@Ru@PEI@Nafion nanofiber mat (PAN@Ru@PEI@Nafionnfm). Herein, Ru(bpy)32+ was applied as an ECL reagent, and PEI was selected as a co-reactant due to the abundant tertiary amine groups in its backbone. In order to further improve the ECL efficiency of the Ru(bpy)32+-PEI system, we innovatively loaded Ru(bpy)32+ and PEI into PAN nanofibers simultaneously by a one-step electrospinning technique. As a result, the electronic transmission distance between them was sharply shortened. Meanwhile, with the help of electrostatic interaction between positively charged Ru(bpy)32+ or PEI and negatively charged Nafion, exfoliation of Ru(bpy)32+ and PEI from the PAN nanofiber mat was effectively avoided. As expected, the luminous nanofibers exhibited excellent ECL performance including high efficiency and good stability. On this basis, we fabricated a new self-enhanced ECL sensor with excellent analysis performance. Using α-naphthol as an analytical probe, the sensor showed a wide linear range from 1.0 × 10-12 to 1.0 × 10-7 M with a low detection limit of 1.0 × 10-12 M. When it was applied to detect α-naphthol from carbaryl hydrolysis, the results were well consistent with those obtained from the high efficiency liquid chromatography-diode array detector (HPLC-DAD) method, indicating the potential application of the ECL sensor in real sample assays.
More Related Videos
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019