Related Experiment Video
Updated: Dec 31, 2025

Anteromesial Temporal Lobectomy for Medically Intractable Temporal Lobe Epilepsy: An Operative Study
Published on: August 15, 2025
The superficial temporal artery: A meta-analysis of its prevalence and morphology
Mateusz Koziej1, Jakub Wnuk1, Jakub Polak1
1Department of Anatomy, Jagiellonian University Medical College, Kraków, Poland.
Introduction:
The superficial temporal artery (STA) is a terminal branch of the external carotid artery. It supplies the regions of scalp and face. The morphometrical data concerning STAs are not consistent; therefore, in this systemic review and meta-analysis, we aimed in this to provide an up-to-date data on its anatomic features.
Material And Methods:
In order to do this, PubMed, Embase, ScienceDirect, and Web of Science were searched. We followed the Preferred Reporting Items and Review and Meta-Analyses guidelines for the meta-analysis. Studies that reported the prevalence and anatomical data regarding STA were included in further analyses.
Results:
Out of 1,446 studies initially evaluated, 21 were included in the meta-analysis (874 patients/donors). The STA diameter was 1.5 mm (95% confidence interval [CI]: 1.47-1.53 mm). The frontal and parietal branches of the STA were present in 97.6% (95% CIs: 94.6-99.5%) and 96.4% (95% CIs: 93.5-98.5%) of the cases, respectively. The STA bifurcation point was located above the zygomatic arch in 79.1% (95% CI: 68.0-84.3), below the zygomatic arch in 6.7% (95% CI: 2.4-12.1), and on the zygomatic arch in 11.1% of the cases (95% CI: 5.4-17.5). There was no bifurcation of the STA in 3.1% of the cases (95% CI: 0.4-7.3).
Conclusion:
The most comprehensive analysis of STA morphological features is presented. The results from this evidence-based anatomical study will improve understanding of the clinical STA anatomy, which in turn has major implications for understanding the STA in clinical practice.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...