Impact of Accessory Pathway Location on Electrophysiologic Characteristics and Ablation Success
Mohammadamin Behjati Ardakani1, Faezeh Dehghani, Mohammadtaghi Sarebanhassanabadi
1From the Yazd Cardiovascular Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Background:
To investigate the relationship between the location of accessory pathways, electrophysiologic characteristics, and ablation success in Wolfe-Parkinson-White (WPW) syndrome.
Methods:
Electrophysiologic study was performed in 178 patients for a pre-excitation syndrome. Accessory pathway location, anterograde or retrograde conduction, ablation success, and recurrence rate were evaluated.
Results:
Among 178 patients with WPW syndrome, the most frequent location of the accessory pathway was left lateral (39.3%) which had high ablation success rate (97%) and low recurrence rate (1%). A meaningful relationship exists between accessory pathway location and electrophysiologic characteristics. Ablation success rate was 89.7% and was statistically related to accessory pathway location. Recurrent occurred in 2.9% of our patients and was more frequent in right free wall and PJRT.
Conclusions:
The location of accessory pathways has a great impact on conductivity, ablation success, and recurrence rate in WPW syndrome.