Locations of optimally matched Gabor atoms from ultrasound RF echoes for inter-scatterer spacing estimation
Xiuhua Zeng1, Yufeng Zhang2, Zhiyao Li3
1University Key Lab of Electronic Information Processing of High Altitude Medicine, Yunnan University, Kunming, Yunnan, 650091, China; College of Physics & Electronic Engineering, Qujing Normal University, Qujing, Yunnan, 655011, China.
Background And Objective:
The resolvable scatterer spacing related to biological tissue microstructures is a quantitative signature used for the disease diagnosis and tissue classification. In the present study, a method by locating optimally matched Gabor atoms (LOMGA) from ultrasound RF echo signals is proposed to improve the inter-scatterer spacing (ISS) estimation.
Method:
A series of Gabor atoms are obtained from the signals with a matching pursuit algorithm. Then, the optimum atoms highly correlated with the coherent components are automatically selected according to the second-order difference of the reconstructed signal-to-residue ratio. The distances between the locations of adjacent atoms are applied to estimate the ISSs. In the simulation experiments, four regular degrees of the scatterer distributions are modeled with the Gamma distribution. One hundred sets of ultrasound RF echo signals are simulated based on the regular and diffuse scatterer distributions, and then combined to generate signals with preset coherent-to-diffuse ratios (CDRs). The accuracy performance of the LOMGA method is compared with that based on wavelet transform (WT) algorithm. In the microwave ablation experiments, the ultrasound RF echo signals of the region of interest (ROI) are collected from the normal and coagulated porcine liver tissues. The means and standard deviations of the LOMGA-based ISSs are compared with the WT-based results.
Results:
The results based on simulated signals with CDRs from 10 dB to -10 dB demonstrate that the proposed method improves the estimation accuracies of the mean ISSs by 5.10%, 9.00%, 19.80%, and 23.82%, and reduces the mean standard deviations by 27.20%, 22.50%, 11.50%, and 4.49% more than the WT method for the four regularities, respectively. The performance of the LOMGA method is also verified with the ultrasound RF echo signals from ex vivo porcine liver tissues in microwave ablation experiments.
Conclusions:
It is concluded that the LOMGA method can provide more accurate and stable ISS estimation, which improves the performance of the tissue characterization with ISS-based quantitative ultrasound.
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations