Repeatability imprecision from analysis of duplicates of patient samples and control materials
Anders Kallner1, Elvar Theodorsson2
1Department of Clinical Chemistry, Karolinska University Hospital, Stockholm, Sweden.
Abstract:
Measurement imprecision is usually calculated from measurement results of the same stabilized control material(s) obtained over time, and is therefore, principally, only valid at the concentration(s) of the selected control material(s). The resulting uncertainty has been obtained under reproducibility conditions and corresponds to the conventional analytical goals. Furthermore, the commutability of the control materials used determines whether the imprecision calculated from the control materials reflects the imprecision of measuring patient samples. Imprecision estimated by measurements of patient samples uses fully commutable samples, freely available in the laboratories. It is commonly performed by calculating the results of routine patient samples measured twice each. Since the duplicates are usually analysed throughout the entire concentration interval of the patient samples processed in the laboratory, the result will be a weighted average of the repeatability imprecision measured in the chosen measurement intervals or throughout the entire interval of concentrations encountered in patient care. In contrast, the uncertainty derived from many measurements of control materials over periods of weeks is usually made under reproducibility conditions. Consequently, the repeatability and reproducibility imprecision play different roles in the inference of results in clinical medicine. The purpose of the present review is to detail the properties of the imprecision calculated by duplicates of natural samples, to explain how it differs from imprecision calculated from single concentrations of control materials, and to elucidate what precautions need to be taken in case of bias, e.g. due to carry-over effects.
More Related Videos
Related Concept Videos
Statistical Analysis: Overview
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Data Validation
Key parameters for method validation include: