Related Experiment Video
Updated: Dec 31, 2025

Analysis and Imaging of Osteocytes
Published on: November 29, 2024
Numerical analysis of the flow field in the lacunar-canalicular system under different magnitudes of gravity
Sen Zhao1,2, Haiying Liu3,4, Yonghe Li1,2
1Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin, 300384, People's Republic of China.
Abstract:
Irreversible osteoporosis may occur in astronauts during long-term space flight. The flow field of tissue fluid in the lacunar-canalicular system (LCS) of osteon and the mechanical response of osteocytes to the flow field under different gravity fields were studied by numerical simulation. This study is expected to explain how the decrease in liquid transmission within microgravity can be a cause of osteoporosis in astronauts from the perspective of biomechanics using a fundamental research approach. A 3D axisymmetric fluid-solid coupling finite element model of an osteon with a two-stage pore structure (Haversian canals and lacunar-canalicular network) and osteocytes was established. The model compared the influence of differences in pulsating pressure of arterioles in Haversian canal, from 33 mmHg to 45 mmHg within a microgravity field (0 g), Earth's gravity field (1 g), and a high G gravitational fields (2-8 g). The liquid flow velocity in the LCS within a microgravity field was less than that within a normal gravitational field, and the flow velocity increased with gravitational acceleration. There was a significant liquid pressure gradient in the osteocytes within a normal and higher gravitational field compared with in microgravity. A reduction in the fluid flow velocity and fluid shear stress on osteocytes in different zones in microgravity compared with Earth's gravitational field. For these reasons, possibly causing a decrease in mechanical conduction and biochemical function, even cell death, leads to increased osteoclast activity, eventually causing the loss of a large quantity of bone. Graphical abstract A 3D axisymmetric fluid-solid coupling finite element model of an osteon with a two-stage pore structure was established. The model compared the influence of magnitudes of gravity on liquid transmission in LCS and mechanical response of osteocytes. The mean flow velocity of liquid in various layers (shallow, middle, and deep) increased linearly as acceleration due to gravity increased, and there was a significant liquid pressure gradient in osteocytes within a normal gravitational field compared with in microgravity. In microgravity environment, the osteocytes were unable to experience the pressure difference compared to that of Earth, possibly causing a decrease in mechanical conduction and biochemical function, even cell death, leading to increased osteoclast activity, eventually causing the loss of a large quantity of bone.
Related Concept Videos
Eulerian and Lagrangian Flow Descriptions
The Eulerian method focuses on fixed points in space where fluid properties, such as velocity, pressure, and temperature, are observed as the fluid moves between these...
Design Example: Creating a Hydraulic Model of a Dam Spillway
Application of the Linear Momentum Equation
The goal is to determine the force components in the x and y directions to hold the pipe in place. Since...
Steady, Laminar Flow Between Parallel Plates
Dimensional Analysis
In fluid mechanics, dimensional...
Typical Model Studies

