Contact lens fitting after corneal collagen cross-linking
Preeji Suderman Mandathara1, Parthasarathi Kalaiselvan1, Varsha M Rathi1,2
1Bausch and Lomb Contact Lens Clinic, L V Prasad Eye Institute, Hyderabad, Telangana, India.
Oman Journal of Ophthalmology
|January 7, 2020
Summary
Corneal collagen cross-linking (CXL) did not significantly alter refraction or rigid gas permeable (RGP) lens parameters. However, RGP lenses remain crucial for visual acuity post-CXL in corneal ectasia patients.
Area of Science:
- Ophthalmology
- Corneal Ectasia Research
- Contact Lens Technology
Background:
- Contact lenses (CLs) are essential for vision correction in keratoconus.
- Corneal collagen cross-linking (CXL) is a common treatment for corneal ectasia.
- Assessing the impact of CXL on existing CL fitting is crucial.
Purpose of the Study:
- To evaluate changes in contact lens (CL) fitting after corneal collagen cross-linking (CXL).
- To determine if pre-existing CLs can be reused post-CXL.
Main Methods:
- Retrospective analysis of patient records from a tertiary center.
- Collected data included demographics, pre- and post-CXL refraction, corneal topography, and CL fitting details.
- Compared pre- and post-CXL data using descriptive analysis and paired t-tests.
Main Results:
- No significant changes in refraction or rigid gas permeable (RGP) lens parameters were observed post-CXL.
- Significant changes in RGP lens fitting characteristics were noted, indicating corneal shape alterations.
- Best spectacle-corrected visual acuity and RGP lens visual acuity showed no significant difference pre- and post-CXL.
Conclusions:
- Corneal collagen cross-linking (CXL) does not significantly alter refractive error or RGP lens parameters.
- Post-CXL corneal shape changes necessitate reassessment of RGP lens fitting.
- Rigid gas permeable (RGP) lenses are effective for visual rehabilitation after CXL in corneal ectasia.
More Related Videos
Related Concept Videos
Angle Closure Glaucoma: Treatment
1.1K
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
1.1K
Focusing of Light in the Eye
5.1K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...