Related Experiment Video
Updated: Dec 31, 2025

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Effect of Hemodynamic Changes in Plasma Propofol Concentrations Associated with Knee-Chest Position in Spinal
Daniela Chalo1,2, Sara Pedrosa2, Pedro Amorim3
1Institute of Neurosciences of Castilla y Leon, INCyL, IBSAL, University of Salamanca, Salamanca, Spain.
Background:
Anesthesia induction and maintenance with propofol can be guided by target-controlled infusion (TCI) systems using pharmacokinetic (Pk) models. Physiological variables, such as changes in cardiac output (CO), can influence propofol pharmacokinetics. Knee-chest (KC) surgical positioning can result in CO changes.
Objectives:
This study aimed to evaluate the relationship between propofol plasma concentration prediction and CO changes after induction and KC positioning.
Methods:
This two-phase prospective cohort study included 20 patients scheduled for spinal surgery. Two different TCI anesthesia protocols were administered after induction. In phase I (n = 9), the loss of consciousness (LOC) concentration was set as the propofol target concentration and CO changes following induction and KC positioning were quantified. In phase II (n = 11), based on data from phase I, two reductions in the propofol target concentration on the pump were applied after LOC and before KC positioning. Propofol plasma concentrations were measured at different moments in both phases: after induction and after KC positioning.
Results:
Schnider Pk model showed a good performance in predicting propofol concentration after induction; however, after KC positioning, when a significant drop in CO occurred, the measured propofol concentrations were markedly underestimated. Intended reductions in the propofol target concentration did not attenuate HD changes. In the KC position, there was no correlation between the propofol concentration estimated by the Pk model and the measured concentration in plasma, as the latter was much higher (P = 0.013) while CO and BIS decreased significantly (P < 0.001 and P = 0.004, respectively).
Conclusions:
Our study showed that the measured propofol plasma concentrations during the KC position were significantly underestimated by the Schnider Pk model and were associated with significant CO decrease. When placing patients in the KC position, anesthesiologists must be aware of pharmacokinetic changes and, in addition to standard monitoring, the use of depth of anesthesia and cardiac output monitors may be considered in high-risk patients.
Related Concept Videos
Parenteral Anesthetics: Overview
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Spinal Anesthesia
Factors Affecting Drug Distribution: Organ Perfusion Rate
Perfusion rate-limited distribution relies on the...

