Dynamic Multiparameter Platelet Function Assessment Using a Capacitive Biosensor
Published on: May 2, 2025
Point-of-Care Assessment of Hemostasis with a Love-Mode Surface Acoustic Wave Sensor
Xi Chen1, Meng Wang1, Gang Zhao1
1Department of Electronic Science and Technology , University of Science and Technology of China , Hefei 230027 , Anhui , China.
Monitoring of the hemostasis status is essential for therapeutic anticoagulants, undergoing surgery, cardiovascular diseases, etc. Although the clinical values of conventional blood coagulation tests have been well demonstrated, these devices have limitations such as large and expensive equipment, excessive sample volumes, long turnaround times, and difficulty in miniaturization for point-of-care use. Here, we present a novel strategy to evaluate blood hemostasis using the single-port Love-mode surface acoustic wave (SLSAW) sensor. The SLSAW sensor was designed as a plug-and-play-type unit for disposable use and operated under the harmonic resonant mode to produce frequency response to the blood coagulation cascade. Compared with a quartz crystal microbalance, Lamb wave, and film bulk acoustic resonator, the frequency shift of SLSAW was significantly increased, ranging from approximately 8960 to 10 368 kHz, which indicated enhancement of the signal-to-noise ratio. To demonstrate the feasibility of the SLSAW, studies were carried out to examine the effects of temperature and clotting reagents on coagulation times and kinetics. Activated partial thromboplastin times of plasma were validated by comparing with SYSMEX CA-7000 with the correlation (R2) as 0.996. In terms of coagulation kinetics, reaction time, clot formation time, maximum frequency shift, and clot formation rate of whole blood correlated well with corresponding parameters of the standard thromboelastography (TEG) analyzer (R2 = 0.9942, 0.9868, 0.9712, and 0.9939, respectively). The SLSAW sensor, with the advantages of low cost, small size, little sample consumption (1 μL), disposable use, and simple operation, is a promising tool for point-of-care diagnosis of hemostasis.
Monitoring of the hemostasis status is essential for therapeutic anticoagulants, undergoing surgery, cardiovascular diseases, etc. Although the clinical values of conventional blood coagulation tests have been well demonstrated, these devices have limitations such as large and expensive equipment, excessive sample volumes, long turnaround times, and difficulty in miniaturization for point-of-care use. Here, we present a novel strategy to evaluate blood hemostasis using the single-port Love-mode surface acoustic wave (SLSAW) sensor. The SLSAW sensor was designed as a plug-and-play-type unit for disposable use and operated under the harmonic resonant mode to produce frequency response to the blood coagulation cascade. Compared with a quartz crystal microbalance, Lamb wave, and film bulk acoustic resonator, the frequency shift of SLSAW was significantly increased, ranging from approximately 8960 to 10 368 kHz, which indicated enhancement of the signal-to-noise ratio. To demonstrate the feasibility of the SLSAW, studies were carried out to examine the effects of temperature and clotting reagents on coagulation times and kinetics. Activated partial thromboplastin times of plasma were validated by comparing with SYSMEX CA-7000 with the correlation (R2) as 0.996. In terms of coagulation kinetics, reaction time, clot formation time, maximum frequency shift, and clot formation rate of whole blood correlated well with corresponding parameters of the standard thromboelastography (TEG) analyzer (R2 = 0.9942, 0.9868, 0.9712, and 0.9939, respectively). The SLSAW sensor, with the advantages of low cost, small size, little sample consumption (1 μL), disposable use, and simple operation, is a promising tool for point-of-care diagnosis of hemostasis.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Pulse Assessment Sites
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: