The Efficacy of Technology in Type 1 Diabetes: A Systematic Review, Network Meta-analysis, and Narrative Synthesis
Anthony Pease1,2, Clement Lo1,2, Arul Earnest1
1School of Public Health and Preventive Medicine, Monash University, Melbourne, Australia.
Abstract:
Background: Existing technologies for type 1 diabetes have not been compared against the full range of alternative devices. Multiple metrics of glycemia and patient-reported outcomes for evaluating technologies also require consideration. We thus conducted a systematic review, network meta-analysis, and narrative synthesis to compare the relative efficacy of available technologies for the management of type 1 diabetes. Methods: We searched MEDLINE, MEDLINE In-Process and other nonindexed citations, EMBASE, PubMed, All Evidence-Based Medicine Reviews, Web of Science, PsycINFO, CINAHL, and PROSPERO (inception-April 24, 2019). We included RCT ≥6 weeks duration comparing technologies for type 1 diabetes management among nonpregnant adults (>18 years of age). Data were extracted using a predefined tool. Primary outcomes were A1c (%), hypoglycemia rates, and quality of life (QoL). We estimated mean difference for A1c and nonsevere hypoglycemia, rate ratio for severe hypoglycemia, and standardized mean difference for QoL in network meta-analysis with random effects. Results: We identified 16,772 publications, of which 52 eligible studies compared 12 diabetes management technologies comprising 3,975 participants in network meta-analysis. Integrated insulin pump and continuous glucose monitoring (CGM) systems with low-glucose suspend or hybrid closed-loop algorithms resulted in A1c levels 0.96% (predictive interval [95% PrI] 0.04-1.89) and 0.87% (95% PrI 0.12-1.63) lower than multiple daily injections with either flash glucose monitoring or capillary glucose testing, respectively. In addition, integrated systems had the best ranking for A1c reduction utilizing the surface under the cumulative ranking curve (SUCRA-96.4). While treatment effects were nonsignificant for many technology comparisons regarding severe hypoglycemia and QoL, simultaneous evaluation of outcomes in cluster analyses as well as narrative synthesis appeared to favor integrated insulin pump and continuous glucose monitors. Overall risk of bias was moderate-high. Certainty of evidence was very low. Conclusions: Integrated insulin pump and CGM systems with low-glucose suspend or hybrid closed-loop capability appeared best for A1c reduction, composite ranking for A1c and severe hypoglycemia, and possibly QoL. Registration: PROSPERO, number CRD42017077221.
More Related Videos
Related Concept Videos
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Type 2 and Gestational
Carbohydrate Metabolism
Starch accounts for approximately 60% of the carbohydrates consumed by humans. Since amylase enzymes cannot function in the stomach's acidic environment, starch can only be digested in the mouth and small intestine. Simple sugars are found naturally in milk and fruits in...
Oral Hypoglycemic Agents: Biguanides and Glitazones