Related Experiment Video
Updated: Dec 31, 2025

Author Spotlight: Developing a Disposable Dosator for Preclinical Testing of Dry Powder Inhalers in Small Animal Models
Published on: August 18, 2023
Is "Slow Inhalation" Always Suitable for Pressurized Metered Dose Inhaler?
Daiki Hira1,2,3, Tomoyuki Okuda1, Ayano Mizutani1
1Faculty of Pharmacy, Meijo University, 150 Yagotoyama, Tempaku-ku, Nagoya, Aichi, 468-8503, Japan.
Abstract:
To achieve adequate inhalation therapy, a proper inhalation technique is needed in clinical practice. However, there is limited information on proper inhalation flow patterns of commercial inhalers. Here, we quantitatively estimated airway deposition of two commercial pressurized metered dose inhalers (pMDIs) to determine their optimal inhalation patterns. Sultanol® inhaler (drug particles suspended in a propellant, suspension-pMDI) and QVAR™ (drug dissolved in a propellant with ethanol, solution-pMDI) were used as model pMDIs. Aerodynamic properties of the two pMDIs were determined using an Andersen cascade impactor with human inhalation flow simulator developed by our laboratory. As indices of peripheral-airway drug deposition, fine particle fractions (FPFPA) at different inhalation flow rates were calculated. The time-dependent particle diameters of sprayed drug particles were determined by laser diffraction. On aerodynamic testing, FPFPA of suspension-pMDI significantly decreased depending on the increasing inhalation flow rate, while solution-pMDI achieved higher and constant FPFPA in the range of the tested inhalation flow rates. The particle diameter of solution-pMDI markedly decreased from 5 to 3 μm in a time-dependent manner. Conversely, that of suspension-pMDI remained at 4 μm during the spraying time. Although "slow inhalation" is recommended for pMDIs, airway drug deposition via solution-pMDI (extra-fine particles) is independent of patients' inhalation flow pattern. Clinical studies should be performed to validate instruction for use of pMDIs for each inhaler for the optimization of inhalation therapy.
Related Concept Videos
Inhaled Medications
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Inhalational Anesthetics: Overview
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...