Additional Breast Cancer Detection at Digital Screening Mammography through Quality Assurance Sessions between
Angela M P Coolen1, Bram Korte1, Vivianne C G Tjan-Heijnen1
1From the Department of Radiology, Elisabeth-Tweesteden Hospital, PO Box 90151, 5000 LC, Tilburg, the Netherlands (A.M.P.C., H.W.B.); Department of Radiology, Catharina Hospital, Eindhoven, the Netherlands (B.K.); Department of Internal Medicine, Division of Medical Oncology, GROW, Maastricht University Medical Center, Maastricht, the Netherlands (V.C.G.T.); Department of Epidemiology, Maastricht University, GROW, Maastricht, the Netherlands (A.C.V.); Department of Research and Development, Netherlands Comprehensive Cancer Organisation, Utrecht, the Netherlands (A.C.V.); Department of Radiology, Canisius Wilhelmina Hospital, Nijmegen, the Netherlands (L.E.M.D.); and Dutch Expert Center for Screening, Nijmegen, the Netherlands (L.E.M.D.).
Abstract:
Background Screening technologists may function as readers in breast cancer screening programs. In the Netherlands, they attend quality assurance sessions. The frequency and characteristics of additional breast cancers detected through these sessions have not been reported. Purpose To determine the frequency and characteristics of cancers detected through quality assurance sessions. Materials and Methods This secondary analysis of a prospective cohort included 466 647 screening mammograms obtained between January 1, 2009, and January 1, 2017. Mammograms were single read by certified screening technologists before being double read by two certified screening radiologists who were not blinded to the technologists' reading. The technologists and a coordinating screening radiologist regularly discussed mammograms that the technologists considered suspicious but that did not prompt recall at radiologist double reading. The coordinating radiologist decided whether secondary recall was indicated. During a 2-year follow-up, radiologic and pathologic outcome data for all recalled women were obtained. Characteristics of cancers detected at radiologist double reading and those detected through quality assurance sessions were compared by using χ2 and Fisher exact tests. Results A total of 14 142 women (mean age, 59 years ± 7.8 [standard deviation]; range, 49-75 years) were recalled (recall rate, 3.0% [14 142 of 466 647]): 14 057 after radiologist double reading and 85 by the coordinating radiologists after quality assurance sessions. This resulted in 3156 screening-detected cancers (6.8 cancers detected per 1000 screenings), of which 26 (0.8% of screening-detected cancers [26 of 3156]) were detected after secondary recall through quality assurance sessions. The latter comprised eight ductal carcinomas in situ (88% intermediate or high grade [seven of eight]) and 18 invasive cancers (14 T1a-c and four T2+ cancers, 89% Nottingham grade I or II [16 of 18]). No significant differences in tumor characteristics were found (P values ranging from .22 to .95). Sensitivity of quality assurance sessions for additional cancer detection was 52% (26 of 50; 95% confidence interval: 38%, 66%). Conclusion The role of quality assurance sessions in additional cancer detection is limited. Tumor characteristics did not differ significantly from those of cancers detected at radiologist double reading. © RSNA, 2020.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
06:03Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020