Related Experiment Video
Updated: Dec 31, 2025

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
High parasympathetic activity as reflected by deceleration capacity predicts atrial fibrillation recurrence after
Paul-Adrian Călburean1,2, Thiago Guimarães Osório1, Juan Sieira1
1Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Brussels, Belgium.
Purpose:
High parasympathetic nervous system (PNS) activity is accurately reflected by deceleration capacity (DC) and is involved in atrial fibrillation (AF) recurrence after catheter ablation procedure. When compared with initial catheter ablation procedure, repeated procedures for AF recurrence are followed by a lower success rates, estimated at 50%. Our objective was to evaluate the impact of PNS activity assessed by DC measured before repeated procedure on AF recurrence after repeated procedure.
Methods:
Consecutive patients who underwent an initial catheter ablation procedure for pulmonary vein (PV) isolation and a repeated catheter ablation procedure for AF recurrence were selected. Additional 24-h ambulatory electrocardiographic recording between procedures for DC measurement was required for inclusion. A total of 110 patients were included. Seventy-two patients underwent cryoballoon (CB) ablation and 38 patients underwent radiofrequency (RF) ablation as initial procedure, while all patients underwent RF ablation as repeated procedure.
Results:
DC was higher in cases with right-sided PV reconnection (p = 0.04, OR = 1.38, 95% CI = 1.08-1.78). In patients with CB ablation as initial procedure, DC was higher in patients with PV reconnection (p = 0.03, OR = 1.29, 95% CI = 1.11-1.70), and the number of reconnected PVs was higher in patients with DC ≥ 7.0 ms (median DC value used for dichotomization, p = 0.02, OR = 2.19, 95% CI = 1.10-4.37). In multivariate Cox regression, DC predicted AF recurrence after repeated ablation (p = 0.004, HR = 1.68, 95% CI = 1.35-1.82). In multivariate binary regression, DC predicted persistent AF type recurrence after repeated ablation (p = 0.01, OR = 1.50, 95% CI = 1.10-2.02).
Conclusions:
DC is a novel predictor of AF recurrence and AF recurrence type after repeated catheter ablation procedure. DC may reflect the need of more intensive treatment strategies in patients with high PNS activity.
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias VI: Management of Dysrhythmias