Related Experiment Video
Updated: Dec 31, 2025

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Accuracy of cone beam computed tomography in evaluation of palatal mucosa thickness
Miho Ogawa1, Sayaka Katagiri1, Tatsuro Koyanagi1
1Department of Periodontology, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan.
Aim:
The purpose of this study was to investigate the accuracy of the measurement of palatal mucosa thickness using cone beam computed tomography (CBCT) and to create a conversion formula to evaluate palatal mucosa thickness more accurately. We then evaluated the palatal mucosa thickness in a Japanese population using CBCT and the conversion formula.
Materials And Methods:
We evaluated palatal mucosa thickness in 10 healthy subjects at 15 sites using CBCT, digital impression, and K file. Multiple regression analysis was performed to create a conversion formula to measure thickness accurately. We then obtained CBCT data from 174 patients retrospectively, applied the conversion formula, and evaluated palatal mucosa thickness.
Results:
Sites of measurement affected measurement error. Measurement using CBCT was 0.34 ± 0.04 mm smaller than actual measurement; therefore, a conversion formula was created. Male, age ≥60 years, and probing pocket depth ≥4 mm had significant and positive associations with palatal mucosa thickness; however, no association was observed between bleeding on probing and palatal mucosa thickness.
Conclusion:
CBCT is useful for the noninvasive and accurate measurement of palatal mucosa thickness.