Diuretic response to fluid load in women with urinary incontinence: optimum duration of pad test
B T Haylen1, M I Frazer, J R Sutherst
1Department of Obstetrics and Gynaecology, Royal Liverpool Hospital, Liverpool.
British Journal of Urology
|October 1, 1988
Abstract:
The pattern of bladder filling in response to a 1-litre fluid load was assessed in 20 women with urinary incontinence. The period between 60 and 120 min after the fluid load was identified as best for pad testing because of consistently high bladder volumes and filling rates. A 2-h pad test is recommended as achieving effective and reproducible test conditions for the quantification of urine loss.