Related Experiment Video
Updated: Dec 31, 2025

Calvarial Model of Bone Augmentation in Rabbit for Assessment of Bone Growth and Neovascularization in Bone Substitution Materials
Published on: August 13, 2019
Porous Titanium Granules in comparison with Autogenous Bone Graft in Femoral Osseous Defects: A Histomorphometric
Eudoxie Pepelassi1, Despina Perrea2, Ismene Dontas2
1Department of Periodontology, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece.
Background:
The high resorption rate of autogenous bone is a well-documented phenomenon that can lead to insufficient bone quality and quantity in an augmented area. Nonresorbable bone substitutes might perform better than autogenous bone in certain applications if they are able to provide adequate bone formation and graft osseointegration.
Purpose:
The aim of this study was to compare the osseous regeneration and graft integration in standardized defects in the rabbit femur treated either with porous titanium granules or autogenous osseous graft.
Materials And Methods:
Standardized femoral osseous defects were surgically induced in 45 New Zealand rabbits. Fifteen were treated with porous titanium granules (TIGRAN™-PTG) and membrane (PTGM), 15 with autogenous graft and membrane (AGM), and 15 with membrane alone (CM, control). At six weeks, the defects were assessed histologically and histomorphometrically.
Results:
PTGM as compared to AGM presented similar percentages of newly formed bone tissue, but a significantly higher fraction of the region of interest was filled with the bone substitute material. Accordingly, the composite of new bone plus bone substitute material showed significantly higher volumes for PTGM. Yet, the smaller amount of remaining autogenous bone was far better osseointegrated than the titanium granules, which in large regions showed no connection to newly formed bone. Both PTGM and AGM as compared to CM presented higher values of newly formed bone.
Conclusions:
This study demonstrated that PTG was similarly effective as autogenous osseous graft in achieving osseous regeneration while PTG performed markedly better in graft volume stability. The resulting higher total percentage of new bone combined with the bone substitute material in PTG could provide a superior foundation for implant placement.
More Related Videos
09:09Treatment with Vancomycin Loaded Calcium Sulphate and Autogenous Bone in an Improved Rabbit Model of Bone Infection
Published on: March 14, 2019
13:16Computed Tomography and Optical Imaging of Osteogenesis-angiogenesis Coupling to Assess Integration of Cranial Bone Autografts and Allografts
Published on: December 22, 2015