Related Experiment Video
Updated: Dec 31, 2025

Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
24-hour Intraocular pressure monitoring: the way ahead
Shibal Bhartiya1, Meenakshi Gangwani2, R Balwant Kalra3
1Fortis Memorial Research Institute (FMRI), Gurugram, Haryana, India.
Abstract:
Aim: Large diurnal intraocular pressure (IOP) fluctuation is a single most independent risk factor for glaucoma progression besides raised IOP. The major limitation of Goldman applanation tonometer (GAT) is its inability to measure night IOP without disturbing the patient's sleep. We discussed the methods available for the 24-hour IOP monitoring and its relevance in glaucoma. Methods: A PUBMED search was performed using the 24 Hour tonometry, newer tonometry devices, contact lens sensors, as keywords and all relevant articles were studied. Results and Conclusion: A number of methods are available for the 24 hour IOP monitoring. These devices allow home monitoring of IOP without affecting the daily routine. These devices, like Rebound tonometry, Contact lens sensor (CLS), etc., were briefly discussed. Triggerfish is one CLS device that has the capability to measure IOP without affecting the patient's sleep. Besides being safe and easily tolerable, it has shown reproducible results with other tonometry methods. Triggerfish has also been proven the device of choice in measuring IOP in different glaucoma subtypes and determining the efficacy of treatment in them, the only challenge being that it presently provides data on relative IOP rather than absolute IOP. With future research, triggerfish CLS can become an important device to measure the 24 hour IOP values especially in patients whose office measured IOPs seemingly fit in patient's target range but still the patients' disease shows glaucomatous progression. The utility of this device in relation to progressive vision loss is a matter of future study. Abbreviations: CCT = Central Corneal Thickness; CLS = Contact lens sensor; GAT = Goldmann Applanation Tonometer; IOP = Intraocular Pressure; NTG = Normal Tension Glaucoma; PACG = Primary angle closure glaucoma; POAG = Primary open angle glaucoma; VAS = Visual Analogue Score.
More Related Videos
08:55Translaminar Autonomous System Model for the Modulation of Intraocular and Intracranial Pressure in Human Donor Posterior Segments
Published on: April 24, 2020
07:27Anterior Segment Organ Culture Platform for Tracking Open Globe Injuries and Therapeutic Performance
Published on: August 25, 2021
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Angle Closure Glaucoma: Treatment