Evaluation of accuracy of capillary refill index with pneumatic fingertip compression
Koichiro Shinozaki1,2, Kota Saeki3, Lee S Jacobson4
1The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr., Manhasset, NY, 11030, USA. shino@gk9.so-net.ne.jp.
Abstract:
Capillary refill time (CRT) is a method of measuring a patient's peripheral perfusion status through a visual assessment performed by a clinician. We developed a new method of measuring CRT using standard pulse oximetry sensor, which was designated capillary refill index (CRI). We evaluated the accuracy of CRI in comparison to CRT image analysis. Thirty healthy adult volunteers were recruited for a derivation study and 30 patients in the emergency department (ED) were for validation. Our high fidelity mechanical device compresses and releases the fingertip to measure changes in blood volume using infrared-light (940 nm). CRT was calculated by image analysis software using recorded fingertip videos. CRI and CRT were measured at: room temperature (ROOM TEMP), 15 °C cold water (COLD), and 38 °C warm water (REWARM). Intra-rater reliability, Bland-Altman plots, and correlation coefficients were used to evaluate the accuracy of the novel CRI method. CRI (4.9 [95% CI 4.5-5.3] s) and CRT (4.0 [3.6-4.3]) in the COLD group were higher than the ROOM TEMP and REWARM groups. High intra-rater reliability was observed in both measurements (0.97 [0.95-0.98] and 0.98 [0.97-0.99], respectively). The Bland-Altman plots suggested a systematic bias: CRI was consistently higher than CRT (difference: + 1.01 s). There was a strong correlation between CRI and CRT (r = 0.89, p < 0.001). ED patients had higher CRI (3.91 [5.05-2.75]) and CRT (2.21 [3.19-1.23]) than those of healthy volunteers at room temperature. The same difference and correlation patterns were verified in the ED setting. CRI was as reliable as CRT by image analysis. The values of CRI was approximately 1 s higher than CRT.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of blood pressure in brachial artery(two-step method)
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation