Related Experiment Video
Updated: Dec 31, 2025

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
Published on: December 9, 2010
Simultaneous Multislice Diffusion-Weighted Imaging of the Kidneys at 3 T
Andrej Tavakoli, Julia Krammer1, UIrike I Attenberger2
1From the Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Germany.
Purpose:
The aim of this study was to compare respiratory-triggered diffusion-weighted imaging with simultaneous-multislice acceleration (SMS-RT-DWI) to a standard free-breathing echoplanar DWI (s-DWI) for 3 T renal imaging with respect to image quality and artifacts.
Materials And Methods:
A total of 40 patients who had undergone renal magnetic resonance imaging were included in this retrospective analysis of a prospectively planned cohort study. All examinations were performed on a 3 T whole-body magnetic resonance system. Both s-DWI and SMS-RT-DWI were obtained and images were independently reviewed by 2 radiologists on a 5-point Likert scale with respect to overall preference and image quality, renal edge and parenchymal sharpness, cortico-medullary differentiation, and sequence-related artifacts. Furthermore, discernibility of renal lesions was assessed. The signal-to-noise ratio (SNR) was measured from SNR maps. The derived mean apparent diffusion coefficients were also compared. Qualitative parameters were assessed with the Wilcoxon rank-sum test, and quantitative parameters, with the Student t test.
Results:
Overall image quality, renal edge, and parenchymal sharpness of SMS-RT-DWI were rated as superior to s-DWI by the readers, with fewer sequence-related artifacts (P < 0.01 for all). Lesion discernibility was significantly improved for SMS-RT-DWI (P < 0.01). Both readers preferred SMS-RT-DWI to s-DWI in all cases (40/40). The acquisition time for SMS-RT-DWI was 30% shorter than for s-DWI. Mean SNR heterogeneity of SMS-RT-DWI at b = 800 s/mm was statistically significantly lower than s-DWI, whereas mean SNR was significantly higher for SMS-RT-DWI. Mean apparent diffusion coefficient values from both sequences were comparably homogeneous throughout the kidneys.
Conclusion:
Simultaneous multislice DWI of the kidney at 3 T with respiratory triggering yields substantially improved image quality and lesion discernibility compared with standard single-shot echoplanar DWI with a 30% reduction in scan acquisition time.
Related Concept Videos
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies II: Ultrasonography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...

