Related Experiment Video
Updated: Dec 31, 2025

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Patent foramen ovale closure by using transesophageal echocardiography for cryptogenic stroke: single center
Yangyang Han1,2, Xiquan Zhang3, Fengwei Zhang1
1Department of Cardiovascular Surgery, Qilu Hospital of Shandong University, West Wenhua Road No.107, Lixia District, Jinan, 250012, Shandong Province, China.
Background:
Percutaneous closure of patent foramen ovale (PFO) is routinely performed using plain fluoroscopy in the catheter room. This method results in inevitable radiation damage, adverse effects of contrast agents on kidneys, and high cost. We performed PFO closure with a simplified and economical transesophageal echocardiography (TEE)-only guided approach in the operating room. This study aimed to investigate the feasibility, safety, and effectiveness of the percutaneous closure of PFO by only using TEE.
Methods:
We reviewed the medical records of patients who underwent percutaneous PFO closure at our center from December 2013 to December 2017. A total of 132 patients with PFO and cryptogenic strokes underwent PFO closure by using cardi-O-fix PFO device under TEE guidance. The participants comprised 64 and 68 male and female patients, respectively. The mean age and body weight of the patients were 39.40 ± 13.22 years old (12-68 years old) and 65.42 ± 9.70 kg (40-95 kg), respectively. All patients only received aspirin (3-5 mg/kg body weight, oral administration) for 6 months. Contrast-enhanced transthoracic echocardiography (c-TTE) with Valsalva maneuver was performed during follow-up, and questionnaire surveys were obtained at 3, 6, and 12 months after the procedure.
Results:
All (100%) patients were successfully closed. Follow-ups were conducted for 13 months to 48 months, with an average of 27 months. No severe complications were found during the follow-up period. Paroxysmal atrial fibrillation occurred in 4 patients within 3 months after the procedure. No recurrent stroke or death occurred in all patients during the follow-up period. Transient ischemic attack occurred in one patient 6 months after the procedure. Ten (7.6%) patients had a right-to-left shunt, as demonstrated by c-TTE at 12 months of follow-up. Among the 57 patients suffering from migraine, significant relief or resolution was reported by 42 (73.7%) patients.
Conclusion:
TEE-only guided PFO closure was a safe, feasible, and effective method that did not require the use of X-rays and contrast agents.