Related Experiment Video
Updated: Dec 31, 2025

Using a Real-Time Locating System to Measure Walking Activity Associated with Wandering Behaviors Among Institutionalized Older Adults
Published on: February 8, 2019
Correlation of activity data in normal dogs to distance traveled
Bishoy S Eskander1, Megan Barbar1, Richard B Evans1
1University of Minnesota, College of Veterinary Medicine, Department of Veterinary Clinical Sciences, 1365 Gortner Avenue, St. Paul, Minnesota 55108, USA (Eskander, Evans, Conzemius); Comparative Pain Research Laboratory, Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, 1060 William Moore Drive, Raleigh, North Carolina 27607, USA (Barbar, Enomoto, Lascelles); Center for Pain Research and Innovation, UNC School of Dentistry, 385 South Columbia Street, Chapel Hill, North Carolina 27599, USA (Lascelles); Center for Translational Pain Research, Department of Anesthesiology, Duke University, 134 Research Drive, Durham, North Carolina 27710, USA (Lascelles).
Abstract:
The objective of this study was to explore the mathematical relationships between independent variables (patient morphometrics and treadmill speed) and dependent variables (accelerometer or pedometer output) when evaluating data from accelerometers and pedometers in dogs. Twenty dogs took part in 3 randomized activities, consisting of exercise on a treadmill at 1.0, 1.5, and 2.0 m/s for a total distance of 1 km at each speed. Dogs simultaneously wore both an accelerometer and a pedometer. Statistical analysis used multiple regression models to discover the relationships between independent and dependent variables. A formula was developed to predict the distance traveled by a dog based on its morphometrics and activity monitor output. Shoulder height had stronger correlations to accelerometer and pedometer outputs than other morphometric variables. As shoulder height increased, all accelerometer and pedometer outputs decreased. As treadmill speed increased, both accelerometer and pedometer step counts decreased, while accelerometer activity counts increased. According to a formula derived to predict the total distance traveled using patient shoulder height and accelerometer or pedometer output, pedometer steps were the most accurate predictor of distance traveled. Accelerometer steps were less accurate when using the same model. Accelerometer activity counts did not reveal a meaningful predictive formula. The results of this study indicate that patient morphometrics and treadmill speed (as a measure of intensity) influenced accelerometer and pedometer data. The pedometer data more precisely and accurately estimated the distance traveled based on step counts and patient shoulder height. In normal dogs, accelerometer and pedometer steps may reasonably estimate distance traveled.
Related Concept Videos
Distance Measurements by Taping
Coefficient of Correlation
If you suspect a linear relationship between x and y, then r can measure how strong the linear relationship is.
What the VALUE of r tells us:
The value of r is always between –1 and +1: –1 ≤ r ≤ 1.
The size of the correlation r indicates the...
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if:
Correlation of Experimental Data
For example, a spherical particle moving through a viscous fluid experiences drag. Dimensional analysis shows that the drag force depends on the particle's diameter, velocity,...
Distance Corrections
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...