Related Experiment Video
Updated: Aug 11, 2026

Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
Comparison of two techniques for obtaining samples for coagulation studies: venipuncture and intraarterial line
1Special Care Unit, Memorial Sloan-Kettering Cancer Center, New York, NY.
Insights
Blood coagulation testing from intraarterial catheters is accurate. A 10 ml discard ensures reliable clotting time results, comparable to traditional venipuncture methods.
Area of Science:
- Medical Diagnostics
- Clinical Pathology
- Cardiovascular Research
Background:
- Accurate blood coagulation monitoring is crucial for patient management.
- Intraarterial catheters are increasingly used for continuous monitoring.
- Assessing the reliability of samples from these catheters is essential.
Purpose of the Study:
- To compare blood coagulation values obtained from intraarterial catheters versus venipuncture.
- To determine if intraarterial samples, after a discard volume, accurately reflect clotting time.
- To validate a method for obtaining reliable coagulation data from arterial lines.
Main Methods:
- Prospective study involving 50 consecutive patients.
- Coagulation samples were drawn from intraarterial catheters (10 ml discard) and via venipuncture (0.5 ml discard).
- Statistical analysis using a two-tailed t test for related samples was performed.
Main Results:
- No statistically significant difference was found between coagulation values from intraarterial catheters and venipuncture (p < 0.05).
- Minor variations observed were attributed to sampling error.
- The 10 ml discard volume from intraarterial catheters proved effective.
Conclusions:
- Blood samples from heparinized intraarterial catheters, with a 10 ml discard, accurately assess mean clotting time.
- This method offers a reliable alternative to venipuncture for coagulation testing.
- Findings support the use of intraarterial samples for routine coagulation monitoring.
Abstract:
The purpose of this study was to compare blood coagulation values drawn by venipuncture and from an intraarterial catheter. A 10 ml discard was obtained from 50 consecutive patients before obtaining the coagulation sample from the intraarterial catheter, and a 0.5 ml discard was obtained from the venipuncture specimen. A two-tailed t test for related samples was performed. The results revealed no significant difference between the two methods (p less than 0.05). The small differences seen were attributed to sampling error. These results suggest that blood samples obtained from heparinized intraarterial catheters after a 10 ml discard provide an accurate assessment of patients' mean clotting time.
Related Concept Videos
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Cardiac Catheterization II: Right Heart Catheterization
Venous Thrombosis III: Interprofessional Care
Hemodialysis I: Introduction

