Exploring the value of the double source CT angiography in diagnosing in-stent restenosis in lower limb artery
Jian Yun1,2, Ye Shen1,2, Yun He1,2
1Department of Radiology, Wujin Hospital Affiliated with Jiangsu University, Changzhou, China.
Objectives:
This paper is aimed to explore the value of double source CT angiography (DS-CTA) for diagnosing in-stent restenosis in lower limb artery.
Methods:
From January 2016 to October 2018, all patients with stent in lower limb artery in our hospital were investigated by both DS-CTA and digital subtraction angiography. We measured the minimum lumen diameter and the diameter of the proximal normal vessels under each stent placement. The in-stent restenosis is defined as restenosis when the lumen area decreased by more than 50%. Digital subtraction angiography was performed within 1 week after DS-CT scan. Relationship between DS-CTA and digital subtraction angiography for diagnosing in-stent restenosis in lower limb artery was analyzed. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DS-CTA for diagnosis of in-stent restenosis were analyzed with digital subtraction angiography as the reference standard. A total of 68 stents were placed in 51 patients. Among these patients, 27 cases were diagnosed as in-stent restenosis, presenting as endovascular contrast agent bias or crescent filling defect with the lumen area reducing over 50%, 6 cases of which had no significant in-stent restenosis by digital subtraction angiography analysis. Furthermore, 12 cases were occlusion, in which there was no high density contrast agent in stents; the remaining 41 stents were unobstructed and the contrast agent was filled well, 8 cases of which had significant in-stent restenosis by digital subtraction angiography analysis. In addition, four stents were deformed or distorted. Statistical analysis demonstrated the concentrations of DS-CTA and digital subtraction angiography in diagnosing in-stent restenosis for lower limb artery were closely related, and the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DS-CTA were 72.4%, 84.6%, 77.8%, 80.5%, and 79.4%, respectively.
Conclusion:
DS-CTA has a potential reliability for diagnosis of in-stent restenosis in lower limb artery, which may be further improved to be used for clinical interventional treatment of vascular diseases.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System V: CT
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation