Contrast medium injection protocols for coronary CT angiography: should contrast medium volumes be tailored to body
1Department of Radiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, People's Republic of China.
Aim:
To compare the uniformity and image quality between contrast media injection protocols adjusted for patient body weight (BW) versus body surface area (BSA) during coronary computed tomography (CT) angiography (CCTA).
Materials And Methods:
Consecutive patients (n=489) with suspected coronary artery disease were randomised prospectively to one of two CCTA protocols. In the BW protocol (n=245), patients received individualised iodine delivery rates (≤50 kg: 1 g/s; 51-60 kg: 1.2 g/s; 61-70 kg: 1.4 g/s; 71-80 kg: 1.6 g/s; 81-90 kg: 1.8 g/s; 91-100 kg: 2 g/s; >100 kg: 2.2 g/s). In the BSA protocol (n=244), patients received 9,600 mg iodine/m2 of contrast medium over 12 seconds. Attenuation and image noise were measured. Signal-to-noise ratio and contrast-to-noise ratio were calculated. Image quality was scored. Attenuation was assessed for correlation with BW and BSA using linear regression.
Results:
There were no statistically significant differences in mean arterial attenuation (396.8±47.6 versus 395.8±42.2 HU, p=0.804; 95% confidence interval: -7 to 9), image noise (25.2±5.8 versus 25.5±5.4 HU; p=0.549), signal-to-noise ratio (16.7±4.4 versus 16.6±3.6; p=0.902), contrast-to-noise ratio (25.1±5.8 versus 25.8±7.4; p=0.258) or image quality scores (4.1±0.9 versus 4±0.9; p=0.770) between the BW and BSA protocols. There was no correlation between BW and aortic attenuation or between BSA and aortic attenuation (p=0.324 and 0.932, respectively).
Conclusion:
The average contrast media attenuation and image quality was comparable between BW-adjusted protocol and BSA-adjusted protocol.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies VII: Vascular Imaging