Related Experiment Video
Updated: Dec 31, 2025

Investigating the Three-dimensional Flow Separation Induced by a Model Vocal Fold Polyp
Published on: February 3, 2014
Effects of velopharyngeal openings on flow characteristics of nasal emission
Elias Sundström1, Suzanne Boyce2, Liran Oren3
1Department of Otolaryngology-Head and Neck Surgery, University of Cincinnati, 231 Albert Sabin Way, Cincinnati, OH, 45267, USA. sundstes@uc.edu.
Abstract:
Nasal emission is a speech disorder where undesired airflow enters the nasal cavity during speech due to inadequate closure of the velopharyngeal valve. Nasal emission is typically inaudible with large velopharyngeal openings and very distorting with small openings. This study aims to understand how flow characteristics in the nasal cavity change as a function of velopharyngeal opening using computational fluid dynamics. The model is based on a subject who was diagnosed with distorting nasal emission and a small velopharyngeal opening. The baseline geometry was delineated from CT scans that were taken, while the subject was sustaining a sibilant sound. Modifications to the model were done by systematically widening or narrowing the velopharyngeal opening while keeping the geometry constant elsewhere. Results show that if the flow resistance across the velopharyngeal valve is smaller than resistance across the oral constriction, flow characteristics such as velocity and turbulence are inversely proportional to the size of the opening. If flow resistance is higher across the velopharyngeal valve than the oral constriction, turbulence in the nasal cavity will be reduced at a higher rate. These findings can be used to generalize that the area ratio of the velopharyngeal opening to the oral constriction is a factor that determines airflow characteristics and subsequently its sound during production of sibilant sound. It implies that the highest level of turbulence in the nasal cavity, and subsequently the sound that will likely be perceived as the most severe nasal emission is produced when the size of openings is equal.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
General External Flow Characteristics
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Nose and Nasal Cavity
Free Jet

