Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Computed Tomography Angiography Combined With Knowledge-Based Iterative Algorithm for Transcatheter Aortic Valve
Davide Ippolito, Luca Riva, Cammillo Talei Franzesi
1Department of Medical Physics, "San Gerardo" Hospital, Monza.
Objective:
To evaluate image quality and radiation dose exposure of low-kV setting and low-volume contrast medium (CM) computed tomography angiography (CTA) protocol for transcatheter aortic valve implantation (TAVI) planning in comparison with standard CTA protocol.
Methods:
Sixty-patients were examined with 256-row MDCT for TAVI planning: 32 patients (study group) were evaluated using 80-kV electrocardiogram-gated protocol with 60 mL of CM and IMR reconstruction; 28 patients underwent a standard electrocardiogram-gated CTA study (100 kV; 80 mL of CM; iDose4 reconstruction). Subjective and objective image quality was evaluated in each patient at different aortic levels. Finally, we collected radiation dose exposure data (CT dose index and dose-length product) of both groups.
Results:
In study protocol, significant higher mean attenuation values were achieved in all measurements compared with the standard protocol. There were no significant differences in the subjective image quality evaluation in both groups. Mean dose-length product of study group was 56% lower than in the control one (P < 0.0001).
Conclusion:
Low-kV and low-CM volume CTA, combined with IMR, allows to correctly performing TAVI planning with high-quality images and significant radiation dose reduction compared with standard CTA protocol.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT