Clinical Usefulness of 18F-FC119S Positron-Emission Tomography as an Auxiliary Diagnostic Method for Dementia: An Open-Label, Single-Dose, Evaluator-Blind Clinical Trial
Related Experiment Video
Updated: Dec 30, 2025

Hybrid PET/MRI Imaging of Alzheimer's Disease Based on 18F-AV-1451
Published on: April 18, 2025
Inki Lee1, Hae Ri Na2, Byung Hyun Byun1
1Department of Nuclear Medicine, Korea Cancer Center Hospital, Korea Institute of Radiological and Medical Sciences, Seoul, Korea.
Background And Purpose:
The aim of this study was to determine the diagnostic performance and safety of a new ¹⁸F-labeled amyloid tracer, ¹⁸F-FC119S.
Methods:
This study prospectively recruited 105 participants, comprising 53 with Alzheimer's disease (AD) patients, 16 patients with dementia other than AD (non-AD), and 36 healthy controls (HCs). In the first screening visit, the Seoul Neuropsychological Screening Battery cognitive function test was given to the dementia group, while HC subjects completed the Korean version of the Mini Mental State Examination. Individuals underwent ¹⁸F-FC119S PET, ¹⁸F-fluorodeoxyglucose (FDG) PET, and brain MRI. The diagnostic performance of ¹⁸F-FC119S PET for AD was compared to a historical control (comprising previously reported and currently used amyloid-beta PET agents), ¹⁸F-FDG PET, and MRI. The standardized uptake value (SUV) ratio (ratio of the cerebral cortical SUV to the cerebellar SUV) was measured for each PET data set to provide semiquantitative analysis. All adverse effects during the clinical trial periods were monitored.
Results:
Visual assessments of the ¹⁸F-FC119S PET data revealed a sensitivity of 92% and a specificity of 84% in detecting AD. ¹⁸F-FC119S PET demonstrated equivalent or better diagnostic performance for AD detection than the historical control, ¹⁸F-FDG PET (sensitivity of 80.0% and specificity of 76.0%), and MRI (sensitivity of 98.0% and specificity of 50.0%). The SUV ratios differed significantly between AD patients and the other groups, at 1.44±0.17 (mean±SD) for AD, 1.24±0.09 for non-AD, and 1.21±0.08 for HC. No clinically significant adverse effects occurred during the trial periods.
Conclusions:
¹⁸F-FC119S PET provides high sensitivity and specificity in detecting AD and therefore may be considered a useful diagnostic tool for AD.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)