Flow effects on phenol degradation and sonoluminescence at different ultrasonic frequencies
Richard James Wood1, Cédric Vévert1, Judy Lee1
1Department of Chemical and Process Engineering, University of Surrey, Guildford, Surrey GU2 7XH, United Kingdom.
Abstract:
Current literature shows a direct correlation between the sonochemical (SC) process of iodide oxidation and the degradation of phenol solution. This implies phenol degradation occurs primarily via oxidisation at the bubble surface. There is no work at present which considers the effect of fluid flow on the degradation process. In this work, parametric analysis of the degradation of 0.1 mM phenol solution and iodide dosimetry under flow conditions was undertaken to determine the effect of flow. Frequencies of 44, 300 and 1000 kHz and flow rates of 0, 24, 228 and 626 mL/min were applied with variation of power input, air concentration, and surface stabilisation. Phenol degradation was analysed using the 4-aminoantipyrine (4-AAP) method, and sonoluminescence (SL) images were evaluated for 0.1, 20 and 60 mM phenol solutions. Flow, at all frequencies under certain conditions, could augment phenol degradation. At 300 kHz there was excellent correlation between phenol degradation and dosimetry indicating a SC process, here flow acted to increase bubble transience, fragmentation and radical transfer to solution. At 300 kHz, although oxidation is the primary phenol degradation mechanism, it is limited, attributed to degradation intermediates which reduce OH radical availability and bubble collapse intensity. For 44 and 1000 kHz there was poor correlation between the two SC processes. At 44 kHz (0.01 mM), there was little to suggest high levels of intermediate production, therefore it was theorised that under more transient bubble conditions additional pyrolytic degradation occurs inside the bubbles via diffusion/nanodroplet injection mechanisms. At 1000 kHz, phenol degradation was maximised above all other systems attributed to increased numbers of active bubbles combined with the nature of the ultrasonic field. SL quenching, by phenol, was reduced in flow systems for the 20 and 60 mM phenol solutions. Here, where the standing wave field was reinforced, and bubble localisation increased, flow and the intrinsic properties of phenol acted to reduce coalescence/clustering. Further, at these higher concentrations, and in flow conditions, the accumulation of volatile phenol degradation products inside the bubbles are likely reduced leading to an increase SL.
More Related Videos
09:35Dispersion of Nanomaterials in Aqueous Media: Towards Protocol Optimization
Published on: December 25, 2017
09:05Generation and Quantitative Analysis of Pulsed Low Frequency Ultrasound to Determine the Sonic Sensitivity of Untreated and Treated Neoplastic Cells
Published on: July 22, 2015
Related Concept Videos
Variables Affecting Phosphorescence and Fluorescence
Photoluminescence: Fluorescence and Phosphorescence
A pair of electrons in a...
Photoluminescence: Applications
Physical Properties of Alcohols and Phenols
Alcohols possess a higher boiling point than aliphatic hydrocarbons of similar...
Fluorescence and Phosphorescence: Instrumentation