Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Novel CA-CFAR Approach for Improvement of Doppler Sensor-based Heart Rate Variability Estimation
Abstract:
Heart rate variability is one of major physiological parameters to reflect our stress, which has motivated researchers to investigate a Doppler sensor-based non-contact heartbeat interval estimation algorithm. As one of such methods, we have previously proposed a spectrogram-based method. In this method, the spectrum that might be due to heartbeats is integrated over a spectrogram, and then heartbeat interval is estimated by detecting peaks over the integrated spectrum. However, when a subject moves, undesired peaks with large amplitude appear, which causes the incorrect peak detection. As one of the technique to eliminate the undesired peaks with large amplitude, there is CA-CFAR (Cell Average-Constant False Alarm Rate). CA-CFAR is the technique to detect a signal, when the amplitude of a signal exceeds a threshold calculated with average amplitude of signals before and after the investigated one. However, depending on the duration of body movements, the influence of body movements might be included within the signals used for the threshold calculation, which might results in the detection failure of undesired peaks. This is because the length of GT (Guard Time) is fixed, where GT is the time to prevent the signal used for the threshold calculation from including the investigated signal components. To solve this problem, we propose a novel CA-CFAR in which the length of GT is set as the latest peak interval and only the signal before the investigated one is used so that the influence of body movements does not affect the threshold calculation. Through the experiments where a subject moves, i.e., typing, we confirmed that our spectrogram-based heart rate variability estimation method with the proposed CA-CFAR outperformed the one with CA-CFAR based on fixed GT by the RMSE (Root Mean Squared Error) between the estimated heartbeat interval and the ground truth value of the one.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring pulse
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)