Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
A Simple Unsupervised, Real-time Clustering Method for Arterial Blood Pressure Signal Classification
Abstract:
Biomedical signal analysis often depends on methods to detect and distinguish abnormal or high noise/artifact signal from normal signal. A novel unsupervised clustering method suitable for resource constrained embedded computing contexts, classifies arterial blood pressure (ABP) beat cycles as normal or abnormal. A cycle detection algorithm delineates beat cycles, so that each cycle can be modeled by a continuous time Fourier series decomposition. The Fourier series parameters are a discrete vector representation for the cycle along with the cycle period. The sequence of cycle parameter vectors is a non-uniform discrete time representation for the ABP signal that provides feature input for a clustering algorithm. Clustering uses a weighted distance function of normalized cycle parameters to ignore cycle differences due to natural and expected physiological modulations, such as respiratory modulation, while accounting for differences due to other causes, such as patient movement artifact. Challenging cardiac surgery patient signal examples indicate effectiveness.
More Related Videos
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
05:23Author Spotlight: Noninvasive Cerebral Blood Flow Determination in Human Functional Brain Region for Diagnosis of Neurological Disorders
Published on: May 31, 2024
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...