Related Experiment Video
Updated: Dec 30, 2025

An Experimental Platform to Study the Closed-loop Performance of Brain-machine Interfaces
Published on: March 10, 2011
Sensitivities of Regulation Intensities in Feed-Forward Loops with Multistability
Abstract:
Gene regulatory networks depict the interactions among genes, proteins, and other components of the cell. These interactions are stochastic when large differences in reaction rates and small copy number of molecules are involved. Discrete Chemical Master Equation (dCME) provides a general framework for understanding the stochastic nature of these networks. Here we used the Accurate Chemical Master Equation method to directly compute the exact steady state probability landscape of the feed-forward loop motif (FFL). FFL is one of the most abundant gene regulatory networks motifs where the regulation is carried out from the top nodes to the bottom ones. We examine the behavior of stochastic FFLs under different conditions of various regulation intensities. Under the conditions with slow promoter binding, we show how FFL can exhibit different multistabilities in their landscapes. We also study the sensitivities of regulations of FFLs and introduce a new definition of stochastic sensitivity to characterize how FFLs respond in their probability distributions at the steady state to perturbations of system parameters. We show how change in gene expression under FFL regulations are sensitive to system parameters, including the state of multistability in FFLs.
Related Concept Videos
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
Effects of feedback
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
Cell Signaling Feedback Loops
Negative feedback loops
Most signaling systems have negative feedback loops that can perform different functions such as output limiter, and adaptation.
Output limiter
Upon receiving an input signal, the cellular response rapidly increases until a threshold is reached. Beyond this threshold, a negative feedback loop...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Positive and Negative Feedback Loops
Multi-input and Multi-variable systems
In the absence of...

