Cuff-less Blood Pressure Measurement Using Supplementary ECG and PPG Features Extracted Through Wavelet
Abstract:
Cuff-less blood pressure (BP) is essential for continuous health monitoring to prevent diseases such as hypertension. Due to the discomfort caused by inflation and deflation of the cuff, it is not possible to monitor continuously. Although pulse transit time (PTT) based approach is commonly used, other parameters also vary with BP. Multi-parameter models are developed using regression analysis, to estimate systolic blood pressure (SBP) and diastolic blood pressure (DBP). Hence, the correlation of multiple extracted features with the blood pressure is proved. To achieve this, simultaneous electrocardiogram (ECG) and photoplethysmographic (PPG) along with respective BP data were collected. The developed algorithm uses wavelet transformation on ECG and PPG signals for detection of the occurrence of essential wave points precisely, even in the presence of artifacts. Pulse wave analysis (PWA) is performed to create a feature vector. From the experimental results, it is found that, the SBP model gives mean error of 0.4916 mmHg, with standard deviation of 6.3986 mmHg, whereas for DBP model, mean error is 0.2527 mmHg and standard deviation is 3.2835 mmHg which is acceptable as per the British Hypertension Society (BHS) and Association for the Advancement of Medical Instruments (AAMI) standards. After the removal of BP oddities, mean absolute error improves from 5.625 to 3.854 mmHg for SBP and from 2.564 to 2.144 mmHg for DBP.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...