Estimation of Beat-to-Beat Interval and Systolic Time Intervals Using Phono- and Seismocardiograms
Abstract:
Systolic time intervals Pre-Ejection Period (PEP) and Left Ventricular Ejection Time (LVET) are widely used indicators of cardiac functions. While accurate assessment of them requires costly equipment such as echocardiography devices, a satisfactory estimation can be done by analyzing signals from simple accelerometer and microphone attached to human chest. This paper reports a study where heart rate and the systolic intervals were derived from phonocardiogram (PCG) and seismocardiogram (SCG) simultaneously. Both sensors, the microphone for PCG and the accelerometer for SCG were attached on the chest wall, close to sternum (PCG) and apex of the heart (SCG). The signals were acquired from 10 participants in a 33-minute laboratory protocol with synchronized ECG measurements. Both signals went through an identical processing path: band pass filtering, envelope extraction with Hilbert transformation and peak detection from the envelope signal. In heart rate estimation, PCG and SCG reached 84% and 93% accuracy, respectively. The systolic interval accuracy estimation was based on deviation analysis as the absolute reference values for PEP and LVET were not available. In PEP estimation, the average standard deviations during the rest periods of the protocol were 4 ms for PCG and 8 ms for SCG. In LVET estimation, the deviations were nearly 10 fold compared to PEP. However, the results show that both methods can be used for accurate heart rate estimation and with careful mechanical attachment also PEP can be accurately derived from both. Due to sharper envelope signal waveform, PEP estimation was more accurate with PCG than with SCG.
Related Concept Videos
Beats
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...